Pulse air tightness testing for buildings
Pulse air tightness testing for buildings is considered an alternative method to standard blower door test to measure the air tightness of a building. In June 2022 the published edition of the UK Approved Document L of the Building Regulations, for the first time included approval of an alternative method of airtightness testing to the traditional approach using a fan pressurisation system.
The pulse system approach measures the air leakage of a building at a near ambient pressure level of 4 Pascals (Pa) rather than the standard blower pressure of 50 Pascals (Pa), allowing for a portable compressed-air based unit. This lower pressure testing give an air leakage measurement representative of inhabited conditions of the buildings and simplifies the process of testing removing the need for block up doorways and fans to penetrate the building fabric, so less disruptive.
Whilst the system is approved by the buildings regulations for use in UK buildings industry responses to the Future Homes Standard consultation revealed that there was some lack of confidence in the method, when dealing with very airtight properties, and more generally in comparing the different testing methods. A study published in Energy and Buildings Volume 295 (15 September 2023, 113270) "An investigation into the efficacy of the pulse method of airtightness testing in new build and Passivhaus properties" (Harriet Seddon & Hua Zhong) However showed that when extrapolated up to 50 Pa all fell within the fan pressurisation’s 10% uncertainty range.
The technology was developed by The University of Nottingham, and is now commercially-licensed to tech start-up, Build Test Solutions (BTS), for further information visit https://www.buildtestsolutions.com.
[edit] Related articles on Designing Buildings
- Air change rates.
- Air infiltration.
- Air permeability in isolation rooms.
- Air permeability testing of isolation facilities.
- Air tightness in buildings.
- Approved documents.
- Building emission rate.
- BREEAM Testing and inspecting building fabric.
- Building services compliance with the building regulations.
- Domestic ventilation systems performance.
- Draughts in buildings.
- Dwelling emission rate.
- Dwelling type.
- Energy audit.
- Energy performance certificates.
- HVAC balancing.
- Infrared thermography.
- Let us evolve our buildings from being passive structures to interactive and reactive systems.
- Performance gap.
- Permeability.
- Pervious.
- Porous.
- Standard assessment procedure.
- Target emission rate.
- The history of non-domestic air tightness testing.
- Thermal imaging to improve energy efficiency in building design.
- Featured articles and news
- Energy Efficiency Taskforce disbanded after six months
- As energy efficiency regulations for landlords scrapped.
- Specifying third-party certification
Featured articles and news
Permitted development rights for agricultural buildings
The changes coming into effect as of May 21, 2024.
Biodiversity and the built environment digital series
The nature of building, with CIOB and CWP.
A call for prevention and sensitive re-use.
Risks to the long-term effectiveness of the BNG scheme
National Audit Office publish review of Biodiversity Net Gain.
The CIAT principal designer register
Providing assurance and verification of the capability and competence of registered ATs.
Building Safety recommendations and Northern Ireland
The NI roadmap to improving safety in high rise residential.
Specifying rendered external wall insulation for fire safety
How to interrogate the evidence provided to the specifier.
The benefits of writing articles for your organisation
How to create a profile for your organisation and publish for free.
No Falls Week. The importance of safe working at height
What to expect and what is on offer to avoid accidents.
Scottish Government action to reach net-zero targets
Retrofit expert group highlight critical actions needed.
A forward thinking, inclusive global community of members.
From engineered product life-spans, to their extension.
Circular economy in the built environment
A brief description from 2021. Where are we now?
CLC publishes domestic retrofit competency framework
Roadmap of Skills for net zero.
Understanding is key to conservation.
Open industry engagement survey seeks responses
Institutions and the importance of engagement.